What to know Starting from JMobile Studio 1.80 Service Pack 2 (1.80.02.44) a PDF Viewer software is available for the use on eTop500 serie operator panels with 1Ghz Arm processor (UN30). The operator panel models that have at disposal such feature are: eTop507M eTop507MG eTop510 eTop512 eTop513 eTop515 eTop515G PDF viewer software allows end user […]
Read MoreAuthor: Will Blackwell
What to know On eTOP500 serie panels is possibile to access System Settings in Config Mode by using Tap-Tap procedure, this procedure is not available on Glass panels: eTOP500G and eTOP600. This FAQ will show you how to access System Settings in Config Mode on Glass panels by using two alternative methods. Note: the mentioned […]
Read MoreWhat to know The S7-1200 (starting from firmware version 4.0) and S7-1500 plc serie from Siemens has a built-in firewall, by default the maximum protection level is enabled. To estabilish communication with these plc models it is necessary to enable S7 communications with 3rd party devices, this setting is available from TIA Portal programming software, […]
Read MoreWhat to know JMobile Suite, starting from version 1.91, allow to perform a unattended/silent installation of the whole package including: JMobile Studio Windows Client JMobile PC Runtime What to do To execute a silent installation parameter to be used is: /silent JMobile Suite will be installed into default installation folder. In example for JMobile Suite […]
Read MoreWhat to know JMobile PC Runtime can communicate with Siemens Simatic S7-200 PLC family using the Simatic S7-PPI communication protocol. Note: JMobile Suite version 1.91.00.327 or newer is required. The PPI communication is done trough a 485 2 wires connection, for this reason the communication can be established in two ways: Direct trough a 485 […]
Read MoreWhat to know The Media Player Widget allows, by default, to play videos stored into the internal Flash memory of an operator panel. By the use of JavaScript it is possible to load the video files also from a removable memory storage device such an USB flash drive or an SD card. The same method […]
Read MoreWhat to know In JMobile it is possible to change during runtime the systems of units used by simply applying a dynamic scale factor to the received data. The example explained in this document shows how to configure an application to use 2 different system of units that can be changed during runtime. What to […]
Read MoreWhat to know The Microsoft IIS (Internet Information Services), listen by default on port 80/TCP and on some version of Microsoft Windows like Windows Embedded Standard 7, it’s installed as default. This system service so became in conflict with the default listening service of JMobile PC Runtime. This FAQ explains how to disable the IIS […]
Read MoreWhat to know JMobile PC Runtime can communicate with GE PLCs using the GE SNP communication protocol. Note: JMobile Suite version 1.91.00.327 or newer is required. The SNP communication is generally done trough a 422 4 wires connection, for this reason the communication can be estabilished in two ways: Direct trough a 422 port of […]
Read MoreWhat to know To operate a dimming function in JMobile, you need to work using the 3 Bits Controlled data type. Actually this is a 4 bit data where the 1st bit is used to determine if increment or decrement the value and the remaining 3 bits determines the percentage of dimming applied. What to […]