What to know The Codesys V2.3 internal plc provides the support for the communication with Modbus TCP Ethernet I/Os. The System provide the possibilities to select the Devices from 3 producers: Beckhoff, Wago and Weidmuller, and provides also a generic model called STD_MODBUS. The Modbus physical addressing of the I/O resources for the predefined producers […]
Read MoreAuthor: Will Blackwell
What to know Enhanced Write Filter (or EWF) is a component of Windows XP Embedded and Windows Embedded Standard 7 which stores volume changes on another medium instead of applying them to the original volume. EWF allows the writes to be discarded or committed to the original volume later (either directly or through inaction based […]
Read MoreWhat to know JMobile PC Runtime can communicate with Siemens Simatic S7-200 PLC family using the Simatic S7-PPI communication protocol. Note: JMobile Suite version 1.91.00.327 or newer is required. The PPI communication is done trough a 485 2 wires connection, for this reason the communication can be established in two ways: Direct trough a 485 […]
Read MoreWhat to know The Microsoft IIS (Internet Information Services), listen by default on port 80/TCP and on some version of Microsoft Windows like Windows Embedded Standard 7, it’s installed as default. This system service so became in conflict with the default listening service of JMobile PC Runtime. This FAQ explains how to disable the IIS […]
Read MoreWhat to know JMobile PC Runtime can communicate with GE PLCs using the GE SNP communication protocol. Note: JMobile Suite version 1.91.00.327 or newer is required. The SNP communication is generally done trough a 422 4 wires connection, for this reason the communication can be established in two ways: Direct trough a 422 port of […]
Read MoreWhat to know eTOP-EPC, eTOP-IPC and eCC industrial PC have integrated serial port that can be configured into BIOS. This FAQ will drive you through serial ports configuration. What to do to access BIOS Setup When the system is powered on, the BIOS will enter the Power-On Self Test (POST) routines. These routines perform various […]
Read MoreWhat to know For Exor Industrial Computers eTOP-EPC, eTOP-IPC and Industrial Monitors eTOP-MON series, a specific touch calibration utility is available if calibration of the touch screen if required. What to do Launch the PenMount Control Panel clicking on the desktop icon, system try icon or from the Start Menu of windows. The system lists […]
Read MoreWhat to know Enhanced Write Filter (or EWF) is a component of Windows XP Embedded and Windows Embedded Standard 7 which stores volume changes on another media instead of applying them to the original volume. If the EWF component is enabled on the industrial PC, after the activation of the JMobile Runtime PC license, the […]
Read MoreUniOP is providing the users with the maximum flexibility in the assignment of the IP address. There are several ways to do this and well defined priority rules in order to understand which will be the address used in every situation. The available methods to assign an IP address to a panel are: Manual definition […]
Read MoreWhat to know The UniOP Designer operator panels family support the connection with Siemens S5 plc family, using the SimaticS5 communication protocol. The operator panels have a dedicated Current Loop 20 mA interface on the PLC port that allows the direct connection with the PLC. What stated above is valid with some exceptions listed below: […]
Read More