What to know If you are experiencing slowness on JMobile Studio startup on your laptop/desktop, this could be due to some JMobile Studio license management temporary files that are locked and have not been deleted yet. This could happen after JMobile Studio license activation. What to do Close JMobile Studio programming software. On your computer […]
Read MoreAuthor: Will Blackwell
What to know EXOR HMIs are equipped with serial ports that can be managed by internal controller CODESYS V2 or V3 The sample project attached is made to show the concept of use receiving strings terminated by CR/LF and re-send it out. What to do with CODESYS V2 iPLC on eTOP500/600 The “CODESYS v2 Target […]
Read MoreWhat to know JMobile Studio allow to connect to the SQL4Automation Connector, a software solution for the industrial usage. It connects HMI, PLC and robotic controls directly with SQL databases. HMI directly access SQL databases via the connector and can query data from tables, insert, change and delete data in tables by using SQL commands […]
Read MoreWhat to know CCC certificate (China Compulsory Certification) is the obligatory Chinese certificate for various product groups, in particular for electronic products and machines. Only specific products are subject to this certification. The CCC was effective from May 1, 2003. CCC Certification According to the current directives the CCC certificate is not required for EXOR […]
Read MoreWhat to know eSMART series HMI, as any other Exor HMI, integrate the tap-tap procedure that provide access to System Settings menu. System Settings has several operating modes: Main OS Mode: allow to configure system parameters and update Config OS area Config OS Mode: can be accessed also when panel is facing a software failure […]
Read MoreWhat to know The CODESYS internal PLC is featuring a predefined amount of memory available for code, data and other resources. CODESYS v2 internal PLC Resources Memory size can be read on CODESYS v2 workbench, opening “Resources” tab and then double click on the “Target Settings” icon into. Memory layout is: Code segment = 1MB […]
Read MoreWhat to know The CODESYS internal PLC, available for eTOP Series HMI can support up to 4 contemporary master connections from external devices communicating via CODESYS v2 or v3 Ethernet protocol. Note: the use of the CODESYS v2 internal PLC requires the usage of specific plug-in modules Applies to eTOP Series HMI
Read MoreWhat to know In JMobile Studio you can define: up to 4 communication protocols for eTOP Series HMI, up to 2 communication protocols for eSMART Seris HMI. This FAQ should help you to properly define communication protocols for your project configuration. PLC Network If the HMI needs to be connected to more than one PLC […]
Read MoreWhat to know CODESYS V2.3 and V3 project for eTOP400, 500 and 600 Series internal PLC can be updated or changed while there is NO external connection to the PLC runtime (CODESYS Development System not on-line) Procedure described below allows any users with physical access to panels the updating/install of CODESYS V2.3 and the updating […]
Read MoreWhat to know WAGO Modular-I/O-System (Series 750-753) allow to connect via CODESYS V2 ETH or CODESYS V3 ETH protocol available in JMobile Studio. This FAQ will guide you to properly configure these devices and communication protocols in JMobile Studio. What to do using CODESYS V2 ETH To communicate with a WAGO-Modular I/O-System (Series 750-753) via […]