09 Jun

Can I calibrate the touch of an eTOP500G/eTOP600 serie operator panel?

What to know The touch calibration procedure for the eTOP500G/eTOP600 serie products with capacitive touch screen can be allowed or not, depending on: the panel model, from where Calibration procedure is executed. The table below shows the possible combinations for eTOP500G: CALIBRATION BEHAVIOR 507G/507MG BSP < 1.66.7 507G/507MG BSP >= 1.66.7 510G All BSP 515G […]

Read More
09 Jun

What can I do if I didn’t find the Controller I’m currently using, into protocol configuration?

What to know Communication protocol drivers are updated at every JMobile Studio release. This involve also the list of Controller model that can be selected on Protocol configuration. Anyway if a specific controller model is not listed this doesn’t mean that communication is not possible. What to do On almost all protocol configuration windows a […]

Read More
09 Jun

How can I speed up JMobile Studio startup on my computer?

What to know If you are experiencing slowness on JMobile Studio startup on your laptop/desktop, this could be due to some JMobile Studio license management temporary files that are locked and have not been deleted yet. This could happen after JMobile Studio license activation. What to do Close JMobile Studio programming software. On your computer […]

Read More
09 Jun

How to use HMI serial port from CODESYS v2 or v3 internal PLC?

What to know EXOR HMIs are equipped with serial ports that can be managed by internal controller CODESYS V2 or V3 The sample project attached is made to show the concept of use receiving strings terminated by CR/LF and re-send it out. What to do with CODESYS V2 iPLC on eTOP500/600 The “CODESYS v2 Target […]

Read More
09 Jun

How many HMI and Databases can I connect to SQL4Automation Connector ?

What to know JMobile Studio allow to connect to the SQL4Automation Connector, a software solution for the industrial usage. It connects HMI, PLC and robotic controls directly with SQL databases. HMI directly access SQL databases via the connector and can query data from tables, insert, change and delete data in tables by using SQL commands […]

Read More
09 Jun

Which Exor HMI devices have the CCC certificate?

What to know CCC certificate (China Compulsory Certification) is the obligatory Chinese certificate for various product groups, in particular for electronic products and machines. Only specific products are subject to this certification. The CCC was effective from May 1, 2003. CCC Certification According to the current directives the CCC certificate is not required for EXOR […]

Read More
09 Jun

How to restore an eSMART Series HMI to factory default?

What to know eSMART series HMI, as any other Exor HMI, integrate the tap-tap procedure that provide access to System Settings menu. System Settings has several operating modes: Main OS Mode: allow to configure system parameters and update Config OS area Config OS Mode: can be accessed also when panel is facing a software failure […]

Read More
09 Jun

How much memory is available with CODESYS v2 and v3 internal PLC on eTOP Series HMI?

What to know The CODESYS internal PLC is featuring a predefined amount of memory available for code, data and other resources. CODESYS v2 internal PLC Resources Memory size can be read on CODESYS v2 workbench, opening “Resources” tab and then double click on the “Target Settings” icon into. Memory layout is: Code segment = 1MB […]

Read More
09 Jun

How many connections do CODESYS v2 and v3 internal PLC supports?

What to know The CODESYS internal PLC, available for eTOP Series HMI can support up to 4 contemporary master connections from external devices communicating via CODESYS v2 or v3 Ethernet protocol. Note: the use of the CODESYS v2 internal PLC requires the usage of specific plug-in modules Applies to eTOP Series HMI

Read More
09 Jun

How many communication protocols are supported in a JMobile project?

What to know In JMobile Studio you can define: up to 4 communication protocols for eTOP Series HMI, up to 2 communication protocols for eSMART Seris HMI. This FAQ should help you to properly define communication protocols for your project configuration. PLC Network If the HMI needs to be connected to more than one PLC […]

Read More