H4
Secure Mobility HMI in your Hand
The Handheld range from EXOR is a true HMI in your hand: powerful and easy to program to your needs it remains the perfect choice for safe mobile requirements.
The wireless option of the H4 leads to many positive features being enhanced:
Higher Safety in all areas with no pendant wires to causes issues
Less injury risks
No broken cable downtime
Far less physical fatigue of operator
Increased concentration of operator
The wireless connection is provided by a Unique electronic key which allows for multiple handheld – machine connections to take place simultaneously without any concern for connectivity and of course safety.
Key Features
- Certified Wireless Safety SIL2
- JMobile Integrated
- Easy to Program
- Stunning Design/Ergonomics
- Multiple Integrated Keys
- Potentiometers
- Handwheel
- State Selector
- Bluetooth Safety
- Additional WiFi Connectivity
- Magnets to Hang Devices in Convenient place
- Up to 50 m Connection
Technical Data
System Resources | |
---|---|
Display – Colors | TFT LED – 64K |
Resolution | 480×272, WQVGA |
Brightness | 300 Cd/m² typ. |
Dimming | to 0% |
Touchscreen | Resistive |
CPU | ARM Cortex-A8 – 600 MHz |
Operating System | Microsoft Windows CE 6.0 |
Flash | 128 MB |
RAM | 256 MB |
Real Time Clock, RTC Back-up, Buzzer | Yes |
Handwheel | Yes |
Potentiometer | 2 |
State Selector Switch | 16 Positions |
Emergency stop | Yes |
Enabling Switch | 3 positions |
Interface | |
---|---|
Ethernet | Wi-Fi 802.11 |
USB port | 1 Host V2.0 |
Bluetooth | Reserved for safety functions |
Ratings | |
---|---|
Power supply (charging station | 24 Vdc (18 to 30 Vdc |
Current Consumption | 0.25 A at 24 Vdc (max.) |
Input Protection | Automatic |
Battery | Rechargeable Lithium battery, not user-replaceable |
Environment Conditions | |
---|---|
Operating Temp | +5 to +45°C |
Storage Temp | -20 to +70°C |
Operating / Storage Humidity | 5-85% RH, non condensing |
Protection Class | IP64 |
Dimensions and Weights | |
---|---|
Faceplate LxH | 220×144 mm |
Depth D | 63 mm |
Weight | Approx 0.8 Kg |
Approvals | |
---|---|
CE | Emission EN 61000-6-4 Immunity EN 61000-6-2 for installation in industrial environments |
Safety | 2006/42/EC, EN ISO 13849-1:2008, EN 62061 :2005/A1:2013, EN 60204-1:2006/A1:2009 |
Safety functions | Emergency Stop cat 3, PL d / SIL 2 Enabling cat 3, PL d / SIL 2 State selector, cat 1, PL c / SIL 1 |